HiRay 32
Ultra-High Frequency Digital Radiographic System
Power where it matters - not in your fuse box.
The HiRay 32 operates on a standard 3 kVA single-phase power supply, yet delivers up to 32 kW of generator power. This is made possible by its 500 kHz ultra-high-frequency generator with integrated capacitor storage, combining high performance with low power requirements. A Canon rotating-anode X-ray tube and a 43 × 43 cm caesium-iodide (CsI) fl at-panel detector provide sharp, high-quality images with low radiation dose and rapid image acquisition in approximately three seconds. Dedicated veterinary measurement tools, intelligent exposure settings and a 4-way floating table further streamline the examination workflow, allowing fast, precise and comfortable patient positioning. The result is a powerful, efficient and modern digital X-ray system specifically designed for the demands of veterinary practice.
High performance Flat Panel Detector:
- TFT with direct deposition CsI
- Pixel Size: 139 µm
- Pixel Matrix: 2.912 x 2.912
- AD Conversion: 16 bit
- Spatial Resolution: 3,6 lp/mm
- Imaging Area: 430 mm x 430 mm
- Dimension: 460 mm x 460 mm x 15 mm
Ultra-High Frequency X-Ray Generator:
- High Frequency: 500 kHz
- Capacitor 3 kVA, single phase 220/240 VAC
- Output power: 32 kW, 400 mA and 125 kVp
- kVp Radiographic range, from 40 to 125 kVp
- mA Radiographic range from 10 to 400 mA
- Anatomical program APR (kVp, mAs, AEC, focal spot, etc)
- Two step hand (extended cable length) and foot switch
Canon X-RayTube:
- Maximum: 125 kVp
- Two focal spots: 0,6/1,2 mm and 1,0/2,0 mm
- Anode target angle: 14º
- Heat Capacity: 140 KHU
- Built to last 100.000 exposures
Collimator with LED Light:
- Manual collimator with 6 pair of leaves
- Field LED lamp of 160 LUX
- Light automatic off: 30 seconds
- Retractable measuring tape
Workstation and Software:
- 21" Touch Screen
- Userfriendly quick access user interface
- Preview & Post processing time: 3 sec
- Automatic Pre & Post image enhancement
- Veterinary measurements (VHS, HD, TPLO, TTA etc.)
- Automatic Exposure Parameters (kV, mA, mAs) by entering body thickness
- DICOM 3.0
Stationary 4-way floating table:
- Electromagnetic brakes for all movements
- Lasercontrolled brake release mechanism
- Fixed SID distance 1.000 mm
- Table top movement (longitudinal): +/- 150 mm
- Table top movement (horizontal): +/- 150 mm
- Table top size: 1.500 mm x 610 mm + 300 mm (table extension)
- Table weight capacity: 100 kg
- Overall dimension: 1.500 (1.800) mm x 860 mm x 2.000 mm
- Generator inside the table